Configure <Ipaddr> > Local Net User - Alcatel OmniAccess Wireless System 2.1 Product Manual

Table of Contents

Advertisement

Table -
General (Continued)
Parameter
Priority
Maximum Age (seconds)
Hello Time (seconds)
Forward Delay (seconds)
Command Buttons
Save: Save the current settings.
Audit: Discover the present status of this AP.
Configure <IPaddr> > Local Net User
Use CONFIGURE/Switches and click an IP address under the IP Address column, on the left sidebar
menu, select Security and click Local Net Users, from the User Name column click a User Name to
access this page.
This page allows you to edit information from a template for a Local Net User.
User Name (read-only): User-defined identification.
WLAN ID: The WLAN ID, 1 through 17, or 0 for all WLANs.
Password and Confirm Password: Local Net User password.
Description: Optional user-defined description.
Command Buttons
Save: Add a new Local Net User to the ACS and Alcatel OmniAccess Switch or Appliance
databases and return to this page.
11/5/04
90-100831-300 Rev 2Alcatel OmniAccess Wireless Access Point Quick Installation Guide 204
The value of the writable portion of the Bridge ID, that is, the first
two octets of the (8 octet long) Bridge ID. The other (last) 6
octets of the Bridge ID are given by the value of Bridge MAC
Address. The value may be specified as a number between 0 and
65535. The factory default is 32768.
The value that all bridges use for MaxAge when this bridge is
acting as the root. Note that 802.1D-1990 specifies that the range
for this parameter is related to the value of Stp Bridge Hello Time.
The granularity of this timer is specified by 802.1D-1990 to be
1 second. Valid values are 6 through 40 seconds. The factory
default is 20.
The value that all bridges use for HelloTime when this bridge is
acting as the root. The granularity of this timer is specified by
802.1D-1990 to be 1 second. Valid values are 1 through
10 seconds. The factory default is 2.
The value that all bridges use for ForwardDelay when this bridge
is acting as the root. Note that 802.1D-1990 specifies that the
range for this parameter is related to the value of Stp Bridge
Maximum Age. The granularity of this timer is specified by
802.1D-1990 to be 1 second. An agent may return a badValue
error if a set is attempted to a value which is not a whole number
of seconds. Valid values are 4 through 30 seconds. The factory
default is 15.
Configure <IPaddr> > Local Net User
Configure <IPaddr> > Local Net User
Description

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OmniAccess Wireless System 2.1 and is the answer not in the manual?

Table of Contents