Replacing The Axis-5 Cabling - ABB CRB 15000 Product Manual

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5.3.6 Replacing the axis-5 cabling

Location of the cable harness
The cable harness is located as shown in the figure.
xx2100000061
Summary of the replacement procedure
This is a brief summary of the replacement procedure, containing the major actions
to be performed.
Product manual - CRB 15000
3HAC077389-001 Revision: E
1 Remove the tubular cover.
2 Separate the cabling between the tubular and the tilt (at the axis-4 joint unit).
3 Remove the tilt and place on a workbench.
4 Remove the axis-6 joint unit.
5 Remove the axis-5 cover.
6 Remove the axis-5 joint unit.
7 Replace the cabling.
© Copyright 20212022 ABB. All rights reserved.
5.3.6 Replacing the axis-5 cabling
Continues on next page
5 Repair
277