ABB CRB 15000 Product Manual page 394

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.4.2 Replacing the housing
Continued
2
3
4
5
6
7
Continues on next page
394
Action
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the lower
arm mounting surface, as pointed out in the figure.
Lift the upper arm into mounting position while
inserting the cabling into the lower arm.
Slide the upper arm into place on the guide pins.
Secure the upper arm to the lower arm with all
attachment screws but two.
Pre-tighten the screws crosswise firstly.
Remove the guide pins and fasten the remaining
two screws.
Torque tighten all screws crosswise.
© Copyright 20212022 ABB. All rights reserved.
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001973
xx2000001970
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
xx2000001969
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
xx2000001967
Tightening torque: 4.6 Nm.
Product manual - CRB 15000
3HAC077389-001 Revision: E

Advertisement

Table of Contents
loading