Connecting the axis-3 joint unit cabling
1
2
3
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
Reconnect the connectors to the drive board.
D3.X1 to X1
D3/4.DC+ to DC+
D3/4.DC- to Ground
D3.X4 to X4
D3/4.X2 to X2
D3.X5 to X5
Connect the connectors to each other and snap
them to the cable holders.
J4.DC+ to J4/5.DC+
J4.DC- to J4/5.DC-
J4.CS to J4/5.CS
J4.CP to J4/5.CP
Secure the cables for functional earth and protect-
ive earth with a screw.
© Copyright 20212022 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the housing
Continued
Note
xx2000002068
xx2000002067
Hex socket head cap screw: M3x6
(1 pcs).
Tightening torque: 0.8 Nm.
xx2000001945