Action
Lift the upper arm into mounting position while
inserting the cabling into the lower arm.
Slide the upper arm into place on the guide pins.
Secure the upper arm to the lower arm with all
attachment screws but two.
Pre-tighten the screws crosswise firstly.
Remove the guide pins and fasten the remaining
two screws.
Torque tighten all screws crosswise.
Refit the cable bracket with the four screws.
© Copyright 20212022 ABB. All rights reserved.
5.3.4 Replacing the axis-3 cabling
Note
xx2000001970
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
xx2000001969
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
xx2000001967
Tightening torque: 4.6 Nm.
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Tightening torque: 0.8 Nm
xx2000001966
Continues on next page
5 Repair
Continued
243