5 Repair
5.5.2 Replacing the swing
Continued
2
3
4
5
Continues on next page
528
Action
Remove any old residuals of flange sealant from
the lower arm mounting surface and clean with
isopropanol.
Apply new flange sealant to the corner of the
lower arm mounting surface, as pointed out in the
figure.
CAUTION
The weight of the complete upper and lower arm
together is 18 kg
Lift the upper and lower arm assembly to mount-
ing position and slide it onto the guide pins.
Secure the lower arm to the swing with all attach-
ment screws but two.
Pre-tighten the screws crosswise firstly.
© Copyright 20212022 ABB. All rights reserved.
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001963
xx2000001941
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
xx2000001940
Product manual - CRB 15000