5 Repair
5.3.3 Replacing the axis-2 cabling
Continued
4
5
Refitting the swing cover
1
Continues on next page
214
Action
Secure the cables for functional earth and protect-
ive earth with a screw.
Secure the cabling with cable ties.
Action
Fit the o-ring to its groove.
Replace if damaged.
© Copyright 20212022 ABB. All rights reserved.
Note
Hex socket head cap screw: M3x6
(1 pcs).
Tightening torque: 0.8 Nm.
xx2000001945
Cable ties (3 pcs)
xx2000001946
Note
O-ring: 3HAC061327-047
xx2000001962