Refitting the tilt
1
2
3
4
Product manual - CRB 15000
3HAC077389-001 Revision: E
5.6.5 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Action
Fit two guide pins to the axis-5 joint.
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the tubular
mounting surface, as pointed out in the figure.
Lift the tilt into mounting position while inserting
the cabling into the tubular.
Slide the tilt into place on the guide pins.
© Copyright 20212022 ABB. All rights reserved.
5 Repair
Continued
Note
Guide pin, M3x110: 3HAC077787-
001
Always use guide pins in pairs.
xx2000002146
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000002147