5 Repair
5.3.4 Replacing the axis-3 cabling
Continued
2
3
4
Concluding procedure
1
2
246
Action
Refit the inner covers with four screws each.
Snap the lower arm cover into place.
Secure the cover with four screws.
Action
Calibrate the joint unit torque sensor.
DANGER
Make sure all safety requirements are met when
performing the first test run.
© Copyright 20212022 ABB. All rights reserved.
Note
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (8 pcs)
Tightening torque: 1.4 Nm.
xx2000001947
xx2000001930
Hex socket head cap screw: M3x16
12.9 Lafre 2C2B/FC6.9 (4 pcs)
Tightening torque: 0.45 Nm.
xx2000001929
Note
See
Calibration on page 719
Product manual - CRB 15000
3HAC077389-001 Revision: E