5 Repair
5.4.3 Replacing the tubular
Continued
4
Replacing the tubular
1
Refitting the tubular
Use these procedures to refit the tubular.
Preparations before fitting the joint unit
1
2
3
Continues on next page
412
Action
Remove the tilt from the tubular.
Assist the cabling to be removed while lifting away
the complete tilt.
Place the tilt on a workbench.
Action
Replace the tubular.
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Clean the mounting surface of the joint unit and
the mating surface on the casting with isopropan-
ol.
Joint unit mounting surface is pointed out in the
figure.
Apply a thin layer of flange sealant to the mount-
ing surface. Do not contaminate the radial sealing
with sealant.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
© Copyright 20212022 ABB. All rights reserved.
Note
xx2000002131
Note
Tubular: 3HAC074509-001
Note
The
44.
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001860
The
44.
Product manual - CRB 15000