3
Removing the arm-side interface
1
2
3
4
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
Remove the tool flange adapter.
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
CAUTION
There is cabling connected between the arm-side
interface and the joint unit drive board.
Open the arm-side interface with care to avoid
damage to the cabling or the connector(s).
Do not leave the arm-side interface in location
without being secured with the attachment screws.
Remove the attachment screws.
Loosen the arm-side interface carefully and dis-
connect the connectors from it.
ASI.DC+
ASI.DC-
ASI.X1
© Copyright 20212022 ABB. All rights reserved.
5.3.7 Replacing the axis-6 cabling
Note
xx2000002167
Note
xx2000002550
xx2100000335
Continues on next page
5 Repair
Continued
321