3
4
5
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
Remove two attachment screws and fit two guide
pins to the axis-4 joint unit.
Remove the remaining attachment screws.
Pull out the cabling carefully from the housing.
© Copyright 20212022 ABB. All rights reserved.
5.3.5 Replacing the axis-4 cabling
Note
Guide pin, M3x110: 3HAC077787-
001
Always use guide pins in pairs.
xx2000002079
xx2000002080
xx2000002081
xx2000002127
Continues on next page
5 Repair
Continued
253