5 Repair
5.5.1 Replacing the base
Continued
4
5
6
7
Removing the base cabling
1
Continues on next page
488
Action
Remove the remaining attachment screws.
Use two screws as press out screws in the upcom-
ing step, then dispose all screws.
New screws are included in the spare part delivery
of the joint unit.
Press the joint unit out of position using two of
the previous attachment screws as removal tools.
Remove the joint unit from the base.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
Remove the lifting aid and guide pins.
Action
Remove the attachment screws.
© Copyright 20212022 ABB. All rights reserved.
Note
xx2000002008
xx2000002436
xx2000002014
xx2000001957
Note
xx2100000406