8
9
Closing the housing top cover
1
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
Torque tighten all screws crosswise.
Refit the cable bracket with the two screws.
Secure the cabling with a cable tie.
Action
Check the inner plate gasket.
Replace if damaged.
© Copyright 20212022 ABB. All rights reserved.
5 Repair
5.4.3 Replacing the tubular
Continued
Note
Tightening torque: 1.8 Nm.
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Tightening torque: 0.8 Nm
xx2000002078
Cable ties (1 pcs)
xx2000002077
Note
Gasket: 3HAC075056-001
xx2000002095