5 Repair
5.6.4 Replacing the axis-4 joint unit
Continued
Consumable
Gasket
O-ring
Removing the joint unit
Use these procedures to remove the joint unit.
Preparations before removing the joint unit
1
2
Removing the housing cover
1
Continues on next page
626
Action
Jog the robot to the specified position:
Axis 1: No significance.
Axis 2: 0°
Axis 3: 0°
Axis 4: 0° (home position)
Axis 5: +90°
Axis 6: No significance.
CAUTION
Jog the axis on which the joint unit is to be re-
placed to home position, to achieve correct cable
routing during replacement of the joint unit.
CAUTION
Turn off all supplies for electrical power to the
robot, before starting the repair work.
Action
CAUTION
Make sure that all supplies for electrical power
are turned off.
© Copyright 20212022 ABB. All rights reserved.
Article number
Note
3HAC075056-001
Cover inside housing
Replace if damaged.
3HAC061327-047
Cover for axis 2/3
Replace if damaged.
Note
xx2100000005
Note
Product manual - CRB 15000
3HAC077389-001 Revision: E