5 Repair
5.3.7 Replacing the axis-6 cabling
Continued
Connecting the axis-6 joint unit cabling
1
2
3
4
Continues on next page
334
Action
Reconnect the connectors to the drive board.
D6.X1 to X1
D6.DC+ to +DC
D6.DC- to Ground
D6.X4 to X4
D6.X2 to X2
D6.X5 to X5
Connect the connectors to each other and snap
them to the cable holders.
J7.CS to J7.CS
J7.CP to J7.CP
Secure the cables for functional earth and protect-
ive earth with a screw.
Secure the cabling with cable ties.
© Copyright 20212022 ABB. All rights reserved.
Note
xx2000002164
xx2000002163
Hex socket head cap screw: M3x6
(1 pcs).
Tightening torque: 0.8 Nm.
xx2000002162
Cable ties (3 pcs)
xx2000002161
Product manual - CRB 15000
3HAC077389-001 Revision: E