ABB CRB 15000 Product Manual page 271

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

2
3
4
5
6
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the housing
mounting surface, as pointed out in the figure.
Lift the tubular into mounting position while insert-
ing the cabling into the housing.
Slide the tubular into place on the guide pins.
Secure the tubular to the housing with all attach-
ment screws but two.
Pre-tighten the screws crosswise firstly.
Remove the guide pins and fasten the remaining
two screws.
© Copyright 20212022 ABB. All rights reserved.
5.3.5 Replacing the axis-4 cabling
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000002094
xx2000002082
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111
xx2000002081
Flange socket head screw: M3x20
12.9 Lafre 2C2B/FC6.9+PrO-
COat111
xx2000002079
Continues on next page