5 Repair
5.5.2 Replacing the swing
Continued
Preparations before fitting the joint unit
1
2
3
Refitting the axis-2 joint unit
1
2
Continues on next page
522
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Clean the mounting surface of the joint unit and
the mating surface on the casting with isopropan-
ol.
Joint unit mounting surface is pointed out in the
figure.
Apply a thin layer of flange sealant to the mount-
ing surface. Do not contaminate the radial sealing
with sealant.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Fit the lifting aid to the joint unit.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
© Copyright 20212022 ABB. All rights reserved.
Note
The
44.
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001860
The
44.
Note
The
44.
Joint unit: 3HAC079141-001
Lifting aid: 3HAC077788-001
Screws: M4x35 (4 pcs)
xx2000001957
Product manual - CRB 15000