ABB CRB 15000 Product Manual page 422

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.4.3 Replacing the tubular
Continued
2
3
Connecting the tubular cabling
1
Continues on next page
422
Action
Refit the inner plate with the screws.
Refit the cover with the four screws.
Action
Reconnect the connectors to the drive board.
D3/4.DC+ to DC+
D3/4.DC- to Ground
D3/4.X2 to X2
© Copyright 20212022 ABB. All rights reserved.
Note
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Tightening torque: 1.4 Nm
xx2000002076
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Tightening torque: 0.45 Nm
xx2000002075
Note
xx2000002120
Product manual - CRB 15000
3HAC077389-001 Revision: E

Advertisement

Table of Contents