ABB CRB 15000 Product Manual page 525

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

Connecting the axis-2 joint unit cabling
1
2
3
4
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Reconnect the connectors to the drive board.
D2.X1 to X1
D2.DC+ to DC+
D2.DC- to Ground
D2.X4 to X4
D2.X2 to X2
D2.X5 to X5
Connect the connectors to each other and snap
them to the cable holders.
J2.DC+ to J2.DC+
J2.DC- to J2.DC-
J2.CS to J2.CS
J2.CP to J2.CP
Secure the cables for functional earth and protect-
ive earth with a screw.
© Copyright 20212022 ABB. All rights reserved.
5.5.2 Replacing the swing
Note
The
44.
xx2000002013
xx2000001944
Hex socket head cap screw: M3x6
(1 pcs).
Tightening torque: 0.8 Nm.
xx2000001945
5 Repair
Continued
Continues on next page
525

Advertisement

Table of Contents
loading

Table of Contents