5 Repair
5.6.5 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
3
4
5
Disconnecting the tool flange functional earth cable
1
Continues on next page
662
Action
Loosen the tool flange and remove the cable
bracket by removing the screw.
Cut the cable ties.
Disconnect the CP/CS connectors from the drive
board and remove the tool flange.
Action
Remove the functional earth cable by removing
the screw.