Connecting the base cabling
1
2
3
4
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Reconnect the connectors to the drive board.
D1.X1 to X1
D1.DC+ to DC+
D1.DC- to Ground
Connect the connectors to each other and snap
them to the cable holders.
J1.DC+ to J1.DC+
J1.DC- to J1.DC-
J1.CS to J1.CS
J1.CP to J1.CP
Secure the cables for functional earth and protect-
ive earth with a screw.
© Copyright 20212022 ABB. All rights reserved.
5.3.1 Replacing the base cabling
Note
The
44.
xx2100000405
xx2100000426
Hex socket head cap screw: M3x6
(1 pcs).
Tightening torque: 0.8 Nm.
xx2100000425
5 Repair
Continued
Continues on next page
155