ABB CRB 15000 Product Manual page 239

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

6
7
8
9
10
Connecting the axis-3 joint unit cabling
1
Product manual - CRB 15000
3HAC077389-001 Revision: E
Action
Remove the guide pins and secure the remaining
two attachment screws.
Pre-tighten the screws crosswise.
Torque tighten all screws crosswise.
Remove the lifting aid by removing the screws.
Clean pushed-out flange sealant, if any.
Action
Reconnect the connectors to the drive board.
D3.X1 to X1
D3/4.DC+ to DC+
D3/4.DC- to Ground
D3.X4 to X4
D3/4.X2 to X2
D3.X5 to X5
© Copyright 20212022 ABB. All rights reserved.
5.3.4 Replacing the axis-3 cabling
Note
xx2000002070
Tightening torque: 4.3 Nm.
xx2000002069
Note
xx2000002068
Continues on next page
5 Repair
Continued
239