5 Repair
5.4.1 Replacing the lower arm
Continued
Refitting the lower arm covers
1
2
Continues on next page
370
Action
Wipe, lubricate and fit the o-ring to its groove.
Replace if damaged.
Refit the inner covers with four screws each.
© Copyright 20212022 ABB. All rights reserved.
Note
O-ring: 3HAC061327-044
Grease: 3HAC042536-001 (Shell
Gadus S2)
xx2000001955
xx2000001954
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (8 pcs)
Tightening torque: 1.4 Nm.
xx2000001947
xx2000001930