5 Repair
5.3.6 Replacing the axis-5 cabling
Continued
Refitting the tilt
1
2
3
4
Continues on next page
312
Action
Fit two guide pins to the axis-5 joint.
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the tubular
mounting surface, as pointed out in the figure.
Lift the tilt into mounting position while inserting
the cabling into the tubular.
Slide the tilt into place on the guide pins.
© Copyright 20212022 ABB. All rights reserved.
Note
Guide pin, M3x110: 3HAC077787-
001
Always use guide pins in pairs.
xx2000002146
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000002147
xx2000002131
Product manual - CRB 15000
3HAC077389-001 Revision: E