ABB CRB 15000 Product Manual page 657

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

Removing the joint unit and transition cabling
Use these procedures to remove the joint unit and transition cabling.
Preparations before removing the joint unit and transition cabling
1
2
Removing the tubular cover
1
Removing the axis-4 cover
1
Product manual - CRB 15000
3HAC077389-001 Revision: E
5.6.5 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Action
Jog the robot to the specified position:
Axis 1: No significance.
Axis 2: No significance.
Axis 3: No significance.
Axis 4: No significance.
Axis 5: 0° (home position)
Axis 6: No significance.
CAUTION
Jog the axis on which the joint unit is to be re-
placed to home position, to achieve correct cable
routing during replacement of the joint unit.
CAUTION
Turn off all supplies for electrical power to the
robot, before starting the repair work.
Action
Remove the cover by removing the six screws.
Dispose the screws. New screws must be used
when refitting the cover.
New screws are included in the spare part delivery
of the joint unit.
Action
Remove the cover screws.
© Copyright 20212022 ABB. All rights reserved.
5 Repair
Continued
Note
Note
xx2000002123
Note
xx2000002083
Continues on next page
657