5 Repair
5.4.4 Replacing the wrist housing
Continued
2
3
4
Removing the axis-5 joint unit
1
Continues on next page
440
Action
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J5/6.DC+
J5/6.DC-
J5/6.CS
J5/6.CP
Disconnect the connectors from the drive board.
D4/5.X1
D5.DC+
D5.DC-
D4/5.X4
D5.X2
D4/5.X5
CAUTION
Use tweezers to unlock connectors and pull them
off.
Action
Fit the lifting aid to the joint unit, on the torque
sensor side.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
© Copyright 20212022 ABB. All rights reserved.
Note
xx2000002136
xx2000002137
Tweezers
xx2000002138
Note
Lifting aid: 3HAC077789-001
Screws: M3x12 (4 pcs)
xx2000002139