Set PTSE Holddown
Timer
Sets the PTSE holddown timer value. The PTSE holddown timer value is
the value (expressed in milliseconds) used by the specified node to limit
the rate at which it can send PTSEs. A change to the PTSE holddown
timer value takes place after the next reboot. For more information on
PTSEs, see "PTSE" on page 78 in the Operations Guide.
Command Actions
Enter menu sequence:
Enter a parameter at the prompt
Parameter
interval
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 10 4 3 4 1 5
The following message is displayed:
Default Value is 10 (1 sec), new value is 5
Press ENTER to continue...
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(1) PHD: PTSE Holddown Timer
Format or Range
1 - 30000 milliseconds
1 1 10 4 3 4 1 [parameters]
The PTSE holddown timer values is displayed and is
updated to its new value.
Default value is <x>, new value is <y>