Update Protocol Timer Resolution - 3Com CoreBuilder 7000 Management Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

C
7: C
212
HAPTER
ONFIGURING
Update Protocol
Timer Resolution
V
C
IRTUAL
HANNELS
Updates the timer resolution of the CoreBuilder 7000 family ATM switch.
The default timer resolution is 500 msec (0.5 secs), the minimum timer
resolution is 100 msec, and there is no upper limit. For more
information,see "Display Protocol Timer Resolution" on page 210, and
"Timer Resolution" on page 113 in the Operations Guide.
This command causes the new timer resolution to be activated in the
current session.
The new value of timer resolution is not stored in flash until the Save
Protocol Timer Resolution command described in the next section is
performed.
Command Actions
Enter the menu sequence: (1) SYS: Platform config
Enter a parameter at the prompt
Parameter
Timer Resolution
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 4 1 2 250
The following message is displayed:
Timer resolution was set. Use 'SAVE' to save it on flash.
The timer resolution is updated to 250 msec. All timers are affected.
(1) SET: Switch setup
(4) SIG: Signaling setup
(1) RES: Timer Resolution setup
(2) SET: Set Timer Resolution
Format or Range
in millisec; Range: >=100
1 1 4 1 2
The timer resolution is activated in the current session.
Timer resolution was set. Use 'SAVE' to
set it on flash.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Corebuilder 7000 series

Table of Contents