Set SVCC Calling
Integrity Time
Sets the SVCC calling integrity time. The SVCC calling integrity time is the
default value used to initiate the SVCC integrity timer at the node that
initiates a switched virtual circuit at a logical group node. A change to the
SVCC calling integrity time takes place after the next reboot.
Command Actions
Enter menu sequence:
Enter a parameter at the prompt
Parameter
integrity time
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 10 4 3 4 15
The following message is displayed:
Default value is 35, new value is 20
Press Enter to continue...
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(15) SCI: SVCC Calling Integrity
Time
Format or Range
1-60000 seconds
1 1 10 4 3 4 15
The SVCC calling integrity time is displayed and is
updated to its new value.
Default value is <x>, new value is <y>
Setting the Timers