Reset Atm-Layer Port Statistics - 3Com CoreBuilder 7000 Management Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

C
8: V
242
HAPTER
IEWING
Reset ATM-Layer Port
Statistics
S
TATISTICS
Resets the ATM-layer counters for a specified port. Since the HEC (Header
Error Control) counter appears both in the physical layer statistics (PHY)
and the ATM-layer statistics (ATM), this counter will be reset when you
reset either parameter.
Command Actions
Enter the menu sequence: (4) STS: Statistics
Enter a parameter at the prompt
Parameter
Port ID
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
4 9 1 3.1
The ATM-layer port statistics are reset for port <3.1> and the following
message is displayed.
Reset ATM counters completed successfully.
(9) ATR: ATM layer-reset counters
(1) PRT: Reset counters per port
Format or Range
slot.port (0.0 for all ports)
4 9 1 [parameters]
ATM-layer port statistics for the switch are reset for the
specified port.
Reset ATM counters completed
successfully.