Table 63 PTSE Table Parameters - Statistics Section
Parameter
DTL Count Originator
Crankback Count
Originator
Alternate DTL Count
Originator
Route Fail Count
Originator
Route Fail Unreachable
Originator
Example
Enter:
1 1 10 4 7 1
Showing PNNI Information
Description
The total number of DTL stacks that this switching
system has originated and placed into signaling
messages. This value includes the number of alternate
route DTL stacks (see Alternate DTL Count Originator
below).
The total number of connection setup messages
including DTL stacks originated by this switching
system that have cranked back to this switching
system at all levels of the hierarchy.
The number of alternate route DTL stacks computed
by this switching system in response to crankbacks.
The total number of times that the switching system
failed to compute a viable partial DTL stack as an entry
border node for some call. It indicates the number of
times a call was either cleared or cranked back from
this switching system due to border routing failure.
The total number of times where the switching system
failed to compute a viable DTL stack as the destination
was unreachable.