Update Link-Failure Indicator Sensitivity - 3Com CoreBuilder 7000 Management Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

C
5: C
126
HAPTER
ONFIGURING
Update Link-Failure
Indicator Sensitivity
I
M
NTERFACE
ODULES
Enables or disables the link-failure mechanism for the CoreBuilder 7000
family ATM switch and sets its sensitivity. For more information,
"Link-Failure Detection Sensitivity Control" on page 129 in the
Operations Guide.
Command Actions
Enter the menu sequence: (1) SYS: Platform config
Enter a parameter at the prompt
Parameter
Port ID
Link-failure detection
enable/disable
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 11 1 2 1
The link-failure status is enabled to low sensitivity.
(1) SET: Switch setup
(11) PLD: Port link down indication
(2) SET: Set&save link down sens
Format or Range
slot.port
0 to disable link-failure detection
1 for low sensitivity link-failure detection
2 for medium sensitivity link-failure detection
3 for high sensitivity link-failure detection
1 1 11 2 [parameters]
The link-failure mechanism is updated immediately and
is saved in flash.
Link-failure mechanism is set to
ENABLED/DISABLED