Set Ptse Lifetime Factor - 3Com CoreBuilder 7000 Management Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

C
13: C
402
HAPTER
ONFIGURING AND
Set PTSE Lifetime
Factor
M
PNNI (F
ANAGING
Sets the PTSE lifetime factor value. The PTSE lifetime factor is the value
used to calculate the initial lifetime of a PTSE. The PTSE refresh interval is
multiplied by this percentage to obtain the initial lifetime factor. A change
to the PTSE lifetime factor value takes place after the next reboot.
Command Actions
Enter menu sequence:
Enter a parameter at the prompt
Parameter
lifetime factor
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 10 4 3 4 6 150
The following message is displayed:
Default Value is 200, new value is 150
Press ENTER to continue...
E
V
O
OR THE
XTENDED
ERSION
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(6) PLT: PTSE Lifetime Factor
Format or Range
101% - 1000%
1 1 10 4 3 4 6 [parameters]
The Hello inactivity factor is displayed and is updated
to its new value.
Default value is <x>, new value is <y>
)