Update Elan Parameters In Les Database - 3Com CoreBuilder 7000 Management Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

C
11: C
326
HAPTER
ONFIGURING
Update ELAN
Parameters in LES
Database
LAN E
S
MULATION
ERVERS
Updates the parameters for the specified ELAN in the LES database.
Table 48 describes the ELAN parameters you can update.
After you use this command to update the parameters of an ELAN in the
LES database you must use LMA to update the parameters of the ELAN in
the LECS database in exactly the same way (see "Update ELAN
Parameters in LECS Database" on page 293).
After updating the parameters, the ELAN is reset, that is, the control
distribute channel to all LECs attached to the ELAN is disconnected.
Command Actions
Enter menu sequence:
Enter a parameter at the prompt
Parameter
ELAN ID
ELAN type
Elan max frame size
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
2 2 4 14 1 1
The following message appears:
ELAN is reset.
The parameters of the ELAN with ID 14 are updated.
(LES)
C
AND
LIENTS
(2) LEM: LAN Emulation
(2) LES: LE Services
(4) EFP: LES Edit ELANs Parameters
Format or Range
1–16
See "Display ELAN Parameters in LES Database" on
page 322
1-Ethernet
2-Token ring (supported by CB7000 HD only
1-1516
2-4544
5-1580
2 2 4 [parameters]
The parameters for the specified ELAN are updated.
The update takes place immediately.
ELAN is reset.
)