Signaling QSAAL Timers (Tenths of second):
for port <3.2>
Param id Param name
-------- ------------------------------ -------
1 Poll UNI 3.0
2 Keep alive UNI 3.0
3 No response UNI 3.0
4 CC UNI 3.0
5 Poll UNI 3.1
6 Keep alive UNI 3.1
7 No response UNI 3.1
8 CC UNI 3.1
9 Idle UNI 3.1
10 Sscop max CC
11 Sscop max PD
12 Sscop max stat
13 Sscop window
SSCOP Timers
Table 31 shows the SSCOP Timers displayed by the command.
Table 31 SSCOP Timers
SSCOP Timer
Description
Poll
Maximum time between transmission of a POLL PDU, when SD
or SDP PDUs are queued for transmission or are outstanding
pending acknowledgment.
Keep-Alive
Maximum time between transmission of POLL PDUs, when no
SD or SDP PDUs are queued for transmission or are outstanding
pending acknowledgment.
No-Response
Maximum time between receipt of a STAT PDU in an active
connection.
CC
The connection control timer determines the time between
transmission of BGN, END, or RS PDUs, as long as an
acknowledgment PDU has not been received.
For stability, make the timer No-Response greater than timer Keep-Alive,
and make timer No-Response greater than timer Poll. Also make timer
No-Response and timer CC greater than the round trip delay.
Signaling Timers
217
Current
value
5
50
500
50
45
50
350
50
750
5
10
67
16