Update ELAN LES-BUS
Address
Updates the LES address of the specified ELAN. Enter the LES address user
part consisting of 6 bytes separated by dots. The last byte is a selector
byte (0-f) that signifies the sequential identifier of the LES in the
CoreBuilder 7000.
Command Actions
Enter menu sequence:
Enter a parameter at the prompt
Parameter
ELAN ID
ATM Address
Direct access sequence:
Command Result
System action taken:
Example
Enter:
2 2 3 1 1 2 c0.da.60. 0.49. 0
The LES-BUS ATM address for the ELAN with ELAN ID #2 is updated.
(2) LEM: LAN Emulation
(2) LES: LE Services
(3) ELN: ELANs Info
(1) LSU: LES Setup
(1) ADR: Set & save LES-BUS address
Format or Range
1–16
See "Display ELAN Parameters in LES Database" on
page 322.
6 bytes of user part, separated by dots
2 2 3 1 1 [parameters]
The LES-BUS ATM addresses for the specified ELAN is
updated. The update takes place immediately.
ELAN Parameters