Set Node
Administrative Status
to DOWN
Updates the administrative status of the PNNI node to DOWN. The
change takes place immediately and is saved in flash memory for the next
reboot.
Command Actions
Enter menu sequence:
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 10 4 3 2 3
The following message is displayed:
Node 1 of 1. PNNI Node Administrative Status is set to DOWN.
The PNNI node administrative status is set to DOWN.
If the status of the PNNI node is set to DOWN and the switch is rebooted,
the status remains DOWN. The PNNI node will only be operative after
setting the administrative status to UP. For details, see "Set Node
Administrative Status to UP" on page 378.
Configuring PNNI Nodes
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(2) ADM: Admin Status
(3) SSD: Set Node Admin Status to
DOWN
1 1 10 4 3 2 3
The PNNI node administrative status is set to DOWN.
The change takes place immediately. The number and
administrative status of the PNNI node are displayed.
Node <m> of <n>. PNNI Node
Administrative Status is set to DOWN.