Chapter 5
Create Circuits and VT Tunnels
NTP-B183 Create a Unidirectional DS-1 Circuit with Multiple
Drops
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
the circuit. If you are already logged in, continue with
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 2
complete the
From the View menu choose Go to Network View.
Step 3
Click the Circuits tab, then click Create.
Step 4
In the Circuit Creation dialog box
Step 5
Note
March 2003
This procedure creates a unidirectional DS-1 circuit with multiple drops
(destinations).
None
NTP-B127 Verify Network Turn Up, page 5-3
As needed
Onsite or remote
Provisioning or higher
"DLP-B60 Log into CTC" task on page
"DLP-B314 Assign a Name to a Port" task on page
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Type—Choose VT.
Size—VT1.5 is the default. You cannot change it.
Bidirectional—Uncheck for this circuit.
Number of circuits—Leave the default unchanged (1).
Auto-ranged—Unavailable when the Number of Circuits field is 1.
State—Choose a service state to apply to the circuit:
IS—The circuit is in service.
OOS—The circuit is out of service. Traffic is not passed on the circuit.
OOS-AINS—The circuit is out of service until it receives a valid signal, at which time the
circuit state automatically changes to in service (IS).
OOS-MT—The circuit is in a maintenance state. The maintenance state does not interrupt traffic
flow; it suppresses alarms and conditions and permits loopbacks on the circuit. Use OOS-MT
for circuit testing or to suppress circuit alarms temporarily. Change the state to IS, OOS, or
OOS-AINS when testing is complete. See the
page
8-8.
If VT circuit source and destination ports are in an OOS_AINS, OOS_MT, or IS state, VT
circuits in OOS_AINS will change to IS even if a physical signal is not present. Refer to the
Cisco ONS 15327 Reference Manual for more information.

NTP-B183 Create a Unidirectional DS-1 Circuit with Multiple Drops

2-23at a node on the network where you will create
Step
2.
(Figure
5-3), complete the following fields:
"DLP-B230 Change a Circuit State" task on
Cisco ONS 15327 Procedure Guide, R4.0
5-16. If not, continue with
Step
3.
5-13