7A-12 HEATING AND VENTILATION SYSTEM
Check
Turn the
Is excessive effort
temperature
required to move the
control
control?
switch
Does the control operate
properly?
Is there any door
binding?
Does the control bind?
Does the control bind?
Is excessive effort
required to move the
control?
Does the control operate
properly without any
interference?
Is the installation good
condition?

HEATER CONTROLS

Yes
Check the cable for improper routing, kinks, wiring
interference or other instrument panel interference.
No
Set the blower switch to 4th.
Repeat to turn the temperature control knob to full hot, then
rapidly to full cold
Yes
Remove the cable from any door that binds on the cable.
Cycle the door manually.
Check the door binding.
No
Repair or replace the problem.
Yes
Check the door seal for proper installation.
No
Check the control for binding.
Yes
Reinstall the cable to the door.
Repair the instrument panel interference with the cable.
No
Remove the cable from the control.
Check the control for binding.
Yes
Replace the control switch.
No
Replace the cable.
Yes
Remove the cable from the control.
Operate the control switch.
No
System OK
Yes
System OK
No
Replace the control switch.
Yes
Check a binding door for the shaft alignment, a bent shaft, a
bent door or warped case and then repair as needed.
No
Repair the door seal or replace as needed.