SSANGYONG Rexton Y200 Manual page 1397

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

7D-20 AUTOMATIC CONTROL HVAC SYSTEM
Step
Repair the faulty circuit between the wiring connector of the blower
8
relay, wiring, blower motor, connector C203, C107.
Is the repair complete?
Measure voltage between terminal 30 of the blower relay and ground.
9
Is the voltage within the specified value?
1. Repair the circuit between terminal 86 of the blower relay and fuse
SB7 in the I/P fuse block.
2. Repair the wiring connector of the blower relay, wiring, blower
10
motor, connector C203, C107.
Is the repair complete?
1. Turn the ignition switch to OFF.
2. Using an ohmmeter, measure the resistance between terminal 85 of
11
the blower relay and ground.
Does the measured resistance indicate 0 Ω?
Repair the faulty circuit between terminal 85 of the blower relay, C104
12
and ground G101.
Is the repair complete?
Replace the blower motor relay.
13
Is the repair complete?
Measure the resistance of the blower motor.
14
Does the measured resistance indicate 0.5 Ω?
Replace the blower motor.
15
Is the repair complete?
Measure the open or short of the circuit between terminal 1 of the
blower connector and terminal 30 of the blower high relay and terminal
16
6 of the power transistor.
Is there any open or short circuit?
Repair the problem in the circuit.
17
Is the repair complete?
Measure the resistance of the circuit from terminal 3 of the power
transistor connector and ground.
18
Does the measured resistance indicate 0 Ω?
Replace the controller.
19
Is the repair complete?
1. Repair the faulty circuit from terminal 3 of the power transistor
connector and terminal 87 of the high blower relay to ground.
20
2. Repair the faulty in the wiring, connector, C109, C209, C104 or
ground G104.
Is the repair complete?
Blower Motor Does Not Run At All (Cont'd)
Action
Yes
No
System OK
-
Go to Step 9
11 - 14 V
Go to Step 10
System OK
-
Go to Step 13
Go to Step 12
System OK
-
System OK
-
Go to Step 15
Go to Step 16
System OK
-
Go to Step 17
Go to Step 18
System OK
-
Go to Step 19
Go to Step 20
System OK
-
System OK
-
SSANGYONG Y200

Advertisement

Table of Contents
loading

Table of Contents