Blower Electrical - SSANGYONG Rexton Y200 Manual

Hide thumbs Also See for Rexton Y200:
Table of Contents

Advertisement

Step
1. Disconnect the power connector from the blower motor.
2. Check the resistance between the 2 terminal of the blower motor
1
connector and each step with the blower switch place each position.
Is the resistance within the specified value?
Replace the blower motor.
2
Is the repair complete?
Check the fuse SB7 (30A) in the engine compartment fuse block.
3
Is the fuse blown?
Replace the fuse.
4
Is the repair complete?
1. Turn the ignition ON.
2. Use the short detector to locate the following possible short:
From the fuse SB7 (30A) in engine compartment fuse block to the
5
blower motor.
From the blower motor to the blower resister block.
From the blower resister block to the blower speed switch.
Is there any short in the above positions?
Repair any short.
6
Is the repair complete?
1. Disconnect the power connector from the blower motor.
2. Use the test lamp to locate a possible short between the terminal 1
of the blower switch connectors and the terminals 6, 3, 5, 4 of the
7
blower switch connectors sequentially.
Does the test lamp light on at any terminal?
Replace the A/C controller switch.
8
Is the repair complete?
Replace the blower resistor.
9
Is the repair complete?
Check the ground of the blower motor and then repair as needed.
10
Is the repair complete?
SSANGYONG Y200
HEATING AND VENTILATION SYSTEM 7A-9

BLOWER ELECTRICAL

Action
Yes
No
Go to Step 2
Go to Step 3
System OK
-
Go to Step 4
Go to Step 5
System OK
-
Go to Step 6
Go to Step 7
System OK
-
Go to Step 8
Go to Step 9
System OK
-
System OK
Go to Step 10
System OK
-

Advertisement

Table of Contents
loading