HEATING AND VENTILATION SYSTEM 7A-11

TOO MUCH HEAT

Yes
Set the temperature control switch to defrost position.
No
Set the mode switch to the vent position.
Yes
Set the blower speed to 4th.
Set the temperature control switch to full hot.
Turn the ignition "ON".
Check the airflow and attachment at the foolr outlet.
No
Check the door travel, the cables, the controls and the
linkage for the defrost position and then repair or replace as
needed.
Yes
Check the door travel, the cables, the controls and the
linkage for the full hot, full cold position and then adjust as
needed.
No
Check for a change in the airflow at different blower speed.
Check the change.
Yes
System OK
No
Go to "Blower Electrical"
Yes
Turn the ignition "OFF".
Turn the temperature control knob to full hot, then rapidly to
full cold.
No
Check the system case for leaks and check the floor outlet
attachment.
Yes
Adjust the vent door to vent mode.
No
Check the door travel, the cables, the controls and the
linkage for the full hot, full cold position and then adjust as
needed.