AUTOMATIC CONTROL HVAC SYSTEM 7D-31

HIGH BLOWER RELAY

1. Remove the high relay connector of the blower
motor.
2. Remove the bolt securing the high relay.
3. Installation should follow the removal procedure
in the reverse order.
YAD7D230
BLOWER MOTOR RESISTANCE
(POWER TRANSISTOR)
1. Remove the connector of the power transistor.
2. Remove two bolts securing the power transistor.
3. Remove the power transistor assembly.
YAD7D240
4. Installation should follow the removal procedure
in the reverse order.
YAD7D250

AIR MIX DOOR ACTUATOR

1. Disconnect the negative battery cable.
2. Remove the glove box.
3. Disconnect the connectors of the air mix door
actuator.
4. Remove three screws securing the mode control
door actuator and heater/air distributor case.
5. Remove the mode control actuator slowly and then
remove the air mix door actuator.
6. Installation should follow the removal procedure
in the reverse order.