10.4 Setting the condition data

10.4.1 Relation between various controls and the condition data

"Condition data" is set in the following cases.
(1) When setting conditions during execution of Section 9.2.21 "JUMP instruction"
(major positioning control)
(2) WHEN SETTING conditions during execution of "high-level positioning control"
The "condition data" to be set includes the setting items from [Da.15] to [Da.19] and
[Da.23] to [Da.26], but the setting requirements and details differ according to the
control method and setting conditions.
The following shows the "condition data" "[Da.15] Condition target" corresponding to
the different types of control.
(The "condition data" settings in this chapter are assumed to be carried out using
GX Works2.)
Control type
[Da.15]
Setting item
(Note-1)
01H: Device X
(Note-1)
02H: Device Y
03H: Buffer memory
(1 word)
04H: Buffer memory
(2 words)
05H: Positioning data
No.
: One of the setting items must be set.
: Setting not possible
(Note-1): Refer to devices X/Y which belongs to Simple Motion module.
REMARK
It is recommended that the "condition data" be set whenever possible with
GX Works2. Execution by sequence program uses many sequence programs and
devices. The execution becomes complicated, and the scan times will increase.
Chapter 10 High-Level Positioning Control
High-level positioning control
Block
Wait
Simultaneous
start
start
start
10 - 16
Major positioning
control
Repeated start
JUMP instruction
(For condition)