Omron NY532-1500 Reference Manual page 278

Ny-series industrial pc platform
Hide thumbs Also See for NY532-1500:
Table of Contents

Advertisement

3 Axis Command Instructions
Ladder Diagram
Main Variables
Name
MC_Axis000
MC_Axis000.MFaultLvl.Active
MC_Axis000.Details.Homed
MC_Axis001
MC_Axis001.MFaultLvl.Active
MC_Axis001.Details.Homed
Pwr1_S
Pwr2_S
CamProfile0
DecRate2
Vel_InVel
Camin_InCam0
Camout_Ex
StartPg
3-194
Data type
Default
_sAXIS_REF
---
BOOL
FALSE
BOOL
FALSE
_sAXIS_REF
---
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
ARRAY[0..360] OF
---
_sMC_CAM_REF
LREAL
10000.0
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
NY-series Motion Control Instructions Reference Manual (W561)
Comment
Axis Variable for the master axis, axis 1.
TRUE while there is a minor fault level
error for axis 1.
TRUE when home is defined for axis 1.
Axis Variable for the slave axis, axis 2.
TRUE while there is a minor fault level
error for axis 2.
TRUE when home is defined for axis 2.
This variable is assigned to the Status
output variable from the PWR1 instance
of the MC_Power instruction. This vari-
able changes to TRUE when the Servo
is turned ON.
This variable is assigned to the Status
output variable from the PWR2 instance
of the MC_Power instruction. This vari-
able changes to TRUE when the Servo
is turned ON.
This is the cam data variable. The array
elements ARRAY[0..N] are set with the
Cam Editor. In this sample, 0 to 360 are
used, but the number of array elements
depends on the settings that you make
with the Cam Editor.
This variable sets the deceleration rate
for execution of MC_CamOut.
This variable is assigned to the InVeloc-
ity output variable from the VEL instance
of the MC_MoveVelocity instruction. It is
TRUE when the target velocity is
reached.
This variable is assigned to the InCam
output variable from the CAMIN instance
of the MC_CamIn instruction. It is TRUE
during cam operation.
The CAMOUT instance of MC_CamOut
is executed while this variable is TRUE.
The Servo is turned ON if this variable is
TRUE and EtherCAT process data com-
munications are established.