Sample Programming - Omron NY532-1500 Reference Manual

Ny-series industrial pc platform
Hide thumbs Also See for NY532-1500:
Table of Contents

Advertisement

3 Axis Command Instructions

Sample Programming

This section shows sample programming where control changes from velocity control to interrupt feed-
ing.
Parameter Settings
The minimum settings required for this sample programming are given below.
Setting Axis Parameters
Axis Types
Axis
Axis 1
Axis 2
Count Modes
Axis
Axis 1
Axis 2
Ring Counters
Axis
Axis 1
Units of Display
Axis
Axis 1
Axis 2
Operation Example
3-122
Axis Type
Servo axis
Servo axis
Count Mode
Rotary Mode
Linear Mode
Modulo maximum
Modulo mini-
position
mum position
360
0
Unit of Display
degree
mm
Axis 2
Sensor 1
Axis 1
NY-series Motion Control Instructions Reference Manual (W561)