Precautions for Correct Use
Precautions for Correct Use
• When using Drive Mode, make sure that you connect the latch signal to the LatchID that you
are going to use.
• The width of the latch signal depends on the performance of the Servo Drive or NX-series
Pulse Output Unit and other factors.
• You must map the following object data when the MC_MoveFeed (Interrupt Feeding) instruc-
tion is executed with InputDrive set to Drive Mode.
Touch probe function (60B8 hex), Touch probe status (60B9 hex), Touch probe pos1 pos
value (60BA hex), and Touch probe pos2 pos value (60BC hex)
If even one of the required objects is not set, a Process Data Object Setting Missing error
(error code 3461 hex) occurs. For details on mapping object data, refer to 2-3 PDO Mapping
and to the NJ/NX-series CPU Unit Motion Control User's Manual (Cat. No. W507) or NY-series
Industrial Panel PC / Industrial Box PC Motion Control User's Manual (Cat. No. W559).
Controller Mode
• You can specify a BOOL variable in the Controller Mode.
• Use TriggerVariable to specify the BOOL variable that you want to use as a trigger.
• The Controller Mode causes a longer delay compared to the Drive Mode. This is due to the
I/O refresh delay that occurs when the trigger input signal is updated in the BOOL variable.
BOOL variable assigned to input signal
Position when trigger signal is input
Precautions for Correct Use
Precautions for Correct Use
If you use Controller Mode, the latch is performed each task period. Therefore, the trigger vari-
able must remain TRUE for at least one task period.
Also, one task period is required between when the trigger variable changes to TRUE and the
MC Function Module processes the latch.
Here, the task period is the primary period if the task is the primary periodic task and the task
period of the priority-5 periodic task if the task is the priority-5 periodic task.
LatchID
• Specify which of the two to use with LatchID. You can use only one of the latches with any one
axis.
• LatchIDs indicate latch circuit 1 and latch circuit 2 in the Servo Drive or NX-series Pulse Output
Unit.
For information on latch IDs, refer to the NJ/NX-series CPU Unit Motion Control User's Manual (Cat.
No. W507) or NY-series Industrial Panel PC / Industrial Box PC Motion Control User's Manual (Cat.
No. W559).
InputDrive
• You can select _mcEncoderMark (Z Phase) or _mcEXT (External Input) as triggers.
NY-series Motion Control Instructions Reference Manual (W561)
Input signal to Input Unit
Axis position
Position (latched position)
3 Axis Command Instructions
Input filter delay + I/O
refresh delay
Time
3
3-111