_sTRIGGER_REF
Name
Meaning
Mode
Mode
LatchID
Latch ID
Selection
InputDrive
Trigger Input
Signal

Function

• When Execute changes to TRUE, the axis travels with absolute travel, relative travel, or velocity con-
trol depending on the MoveMode setting.
• The target position is set in Position (Target Position) for absolute travel. The target distance is set in
Position (Target Distance) for relative travel.
Both travel methods use Velocity (Target Velocity) for travel operation.
• Relative positioning is performed with FeedVelocity from the actual position where the external input
turned ON during travel for the feed distance that is specified with FeedDistance.
• If no interrupt signal is input before the axis reaches the default target position during interrupt feed-
ing in absolute or relative travel mode, the axis stops at the target position. You can specify whether
there is an error output when the axis stops for ErrorDetect (i.e., when there is no interrupt input.) If
you specify an error output, CommandAborted changes to TRUE, and Busy (Executing) and Active
(Controlling) change to FALSE.
• To use interrupt masks, change WindowOnly to TRUE, then specify FirstPosition and LastPosition.
Interrupt feeding is performed for the first interrupt signal generated by the actual position between
the FirstPosition and the LastPosition.
Precautions for Correct Use
Precautions for Correct Use
• Feeding after the interrupt is performed as a relative movement for the distance that is speci-
fied with FeedDistance. If a positive value is specified for FeedDistance, feeding is performed
in the same direction as before the interrupt input, and if a negative value is specified, feeding
is performed in the opposite direction.
• The setting of the Operation Selection at Reversing axis parameter is used for the acceleration
and deceleration rates when reversing to feed.
• If an underflow or overflow would occur for the position after interrupt feeding, an error occurs
when the interrupt input is received. If an interrupt input is received after there is an overflow or
underflow, an axis error will still occur.
Additional Information
Refer to MC_MoveAbsolute on page 3-49 for absolute travel, MC_MoveRelative on page 3-76
for relative travel, MC_MoveVelocity on page 3-83 for velocity control, and WindowOnly on page
3-112 for WindowOnly.
NY-series Motion Control Instructions Reference Manual (W561)
Data type
Valid range
_eMC_TRIG-
0: _mcDrive
GER_ MODE
1: _mcController
_eMC_TRIG-
0: _mcLatch1
GER_ LATCHID
1: _mcLatch2
_eMC_TRIG-
0: _mcEncoderMark
GER_
1: _mcEXT
INPUT_DRIVE
3 Axis Command Instructions
Function
Specify the trigger mode.
0: Drive Mode
1: Controller Mode
Specify which of the two latch functions
to use in Drive Mode.
0: Latch 1
1: Latch 2
Specify the Servo Drive trigger signal
to use in Drive Mode.
0: Z-phase signal
1: External input
3