Ipv6 Access-List - Dell MXL 10GbE Reference Manual

Switch i/o module
Table of Contents

Advertisement

Command
Version 9.2(0.0)
History
Usage
For the new settings to take effect, save the new CAM settings to the startup-
Information
config (write-mem or copy run start), then reload the system.
The total amount of space allowed is 16 FP Blocks. System flow requires three
blocks and these blocks cannot be reallocated.
When configuring space for IPv6 ACLs, the total number of Blocks must equal 13.
Ranges for the CAM profiles are from 1 to 10, except for the ipv6acl profile
which is from 0 to 10. The ipv6acl allocation must be a factor of 2 (2, 4, 6, 8, 10).
Example
Dell#
Dell#configure
Dell(conf)#cam-acl-egress ?
default
l2acl
Dell(conf)#cam-acl-egress l2acl ?
<1-4>
Dell(conf)#cam-acl-egress l2acl 1 ?
ipv4acl
Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ?
ipv6acl
Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl ?
<0-4>
Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl 2

ipv6 access-list

Configure an access list based on IPv6 addresses or protocols.
Syntax
ipv6 access-list access-list-name cpu-qos {permit | deny}
ospfv3
To delete an access list, use the no ipv6 access-list access-list-name
command.
w
Parameters
access-list-
name
cpu-qos
permit
deny
666
Introduced on the MXL 10/40GbE Switch IO Module.
Reset Egress CAM ACL entries to default setting
Set L2-ACL entries
Number of FP blocks for l2acl
Set IPV4-ACL entries
Set IPV6-ACL entries
Number of FP blocks for IPV6 (multiples of 2)
Enter the access list name as a string, up to 140 characters.
Enter the keyword cpu-qos to assign this ACL to control
plane traffic only (CoPP).
Enter the keyword permit to configure a filter to forward
packets meeting this condition.
Enter the keyword deny to configure a filter to drop packets
meeting this condition.
IPv6 Access Control Lists (IPv6 ACLs)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxl 40gbe

Table of Contents